Acoustics for working and recording at home
Acústica en Casa · Updated on · 5 min read
A room with echo makes your voice sound hollow in video calls, podcasts and recordings. It is fixed by absorbing reflections, bringing the microphone closer and controlling background noise. Here are the figures that really exist, what you can do without building work and how to choose panels for a home workspace.
In this guide
Are there acronyms or technical terms you do not understand, such as NRC, RT60 or αw? We explain them step by step in our guide: Acoustics without jargon: what acronyms and numbers mean
Why your voice sounds “hollow”
A microphone picks up two things: your direct voice and the sound that has bounced around the room. At a certain distance, called the critical distance, the level of the reverberation equals that of the direct sound. If the microphone is further away, the room sound dominates and the recording can sound “muddy”, especially in rooms with no acoustic design; bringing it closer to the source gives a recording with clearer detail.
The same happens when listening: INSST’s NTP 503 points out that rooms with very reflective surfaces have long reverberation times, which makes communication difficult.
Which figures really exist
There is no single standard for working from home or recording at home. These are the published references, each for a different case:
- Studies and offices: NTP 503 includes a table from the NBE-CA-82 standard (which predates the Building Code) with a maximum reverberation time of 1 s.
- Classrooms and small conference rooms: CTE DB-HR requires a maximum of 0.7 s in empty classrooms and conference rooms under 350 m³, with speech intelligibility in mind.
- Critical-listening rooms: the EBU Tech 3276 recommendation asks for a nominal RT60 between 0.2 and 0.4 s. It is a criterion for listening, not for a home recording room.
Warning
None of these figures is a requirement for your home office: they are a guide. To find out where your room stands, calculate its RT60 with our calculator.
Besides echo, background noise
NTP 503 identifies intelligible conversations from other people as one of the biggest sources of annoyance in an office, and includes the PSIL index, which indicates up to what distance a normal conversation is intelligible depending on the background noise: about 2.3 m with a PSIL of 45 dB and about 0.75 m with 55 dB. In other words, the more background noise, the sooner a voice stops being understood.
For ventilation system noise, the same NTP states that in offices it should not exceed 35 dBA and that, when the task demands a lot of concentration, the recommended level is 30 dBA. It is a recommendation for offices: it works as a reference for your computer fan or the air conditioning in your home office.
Warning
NTP 503 dates from 1998 and is a good-practice guide, not a mandatory standard; INSST itself recommends taking its publication date into account.
Improvements without building work, from least to most
Start with what costs nothing:
- Bring the microphone closer to your mouth, or use a headset with a microphone: the shorter the distance, the more your direct voice weighs against the room.
- Reduce background noise: close the door and move away or switch off anything that makes continuous noise (a fan, appliances) while you speak or record.
- Add textiles and furniture: a thick rug, curtains and a bookshelf break up reflections; the echo guide has the reference coefficients.
- Acoustic panels on the walls: if the above is not enough, they absorb reflections and lower the room’s RT60.
Tip
Measure before you buy. With the calculator you estimate your room’s RT60 and how many m² of panel you need to get close to your target.
Panels: what to expect and what not to
An acoustic panel absorbs reflections inside the room; it does not stop street or neighbour noise from entering your recording. For that you need insulation: see how to soundproof doors and windows and how to soundproof against neighbours.
When comparing panels, NRC or αw are single figures that are useful for routine uses; ISO 11654 itself makes clear that they are not enough in environments that call for careful acoustic design, where data per frequency are needed. In our panel catalogue we mark where each figure comes from.
If you have monitor speakers on your desk, a stand decouples their vibration from the surface, but it does not change how the room behaves; we explain this in the guide on vibration from appliances and equipment.
Related products
A selection from our catalogue related to this guide.
As an Amazon Associate, I earn from qualifying purchases.
TONOR
TONOR decorative wooden panels, set of 4 of 120×60 cm, teak
No verified acoustic data
- Material
- Wood / MDF
- Size per unit
- 120×60 cm
- Pack contents
- 4 units
- Pack coverage
- 2.88 m²
Set of four slat panels of 120×60 cm (2.88 m²) made of high-density polyester fibre, MDF and solid wood veneer. They can be cut to size and fixed with adhesive or the screws included.
NIC'BRUX
NIC'BRUX PET felt acoustic panels, set of 4 (80×80 cm)
No verified acoustic data
- Material
- PET felt
- Size per unit
- 80×80 cm
80×80 cm PET felt acoustic panels with a contemporary design, wall-mounted with a wedge system, without drilling deep. The title speaks of a set of four; the exact units are still to be confirmed.
UA Acoustics
Pack of 2 acoustic ceiling panels, 50×50 cm, with mounting kit, white
Stated by the seller, with no verifiable test
- Size per unit
- 50×50 cm
- Pack contents
- 2 units
- Pack coverage
- 0.5 m²
Matt white version of the same brand’s pack of two 50×50 cm ceiling panels: HDF board, absorbent filling and a hanging kit included. Same function as the glossy model, a different finish.
Anpro
Anpro, 2 foam pads for studio monitors, 30 × 17 × 3.5 cm
- Material
- Acoustic foam
- Reversible wedge
- 27 × 17 × 2 cm
- Pieces per kit
- 2 pads with wedge
- Angles
- 5 settings
- Size per unit
- 30×17 cm
- Pack contents
- 2 units
Two high-density foam pads of 30 × 17 × 3.5 cm with a reversible 27 × 17 × 2 cm wedge, which give five angles for aiming the monitor at your ear.
Frequently asked questions
What RT60 do I need to record a podcast at home?
There is no official standard for domestic recording rooms. As a reference, the EBU Tech 3276 recommendation asks for between 0.2 and 0.4 s for critical listening, and CTE DB-HR requires a maximum of 0.7 s in small classrooms for speech intelligibility. Bringing your room closer to those values improves clarity, but there is no single correct figure.
Do acoustic panels stop street noise from being heard in my recording?
No. They absorb echo inside the room, but outside noise is only reduced with insulation: mass and sealing of doors and windows. Our guide to soundproofing doors and windows covers what does help.
Are a rug and curtains enough?
They can help a lot in rooms with hard floors and large windows. The way to know whether they are enough is to calculate your room’s RT60 with the calculator and compare it with the references in this guide.
Is it better to bring the microphone closer or to add panels?
They are complementary measures. Bringing the microphone closer reduces the weight of the room in the recording and costs nothing; panels reduce the reverberation of the room itself, which your callers or listeners also hear.
Sources and further reading
What we rely on. The links open in a new tab. Consulted on November 21, 2026.
- INSST, NTP 503: Acoustic comfort: noise in offices — Good-practice guide (1998), not mandatory: reverberation and communication, PSIL index, NBE-CA-82 reverberation times and ventilation noise. In Spanish.
- Simon Fraser University, Handbook for Acoustic Ecology: Critical Distance — Definition of critical distance and the effect of microphone distance on a recording.
- CTE DB-HR, Protection against noise (Spanish Ministry of Transport, Mobility and Urban Agenda) — Reverberation time limit in classrooms and conference rooms (2.2). In Spanish.
- EBU Tech 3276, Listening conditions for the assessment of sound programme material — Nominal RT60 between 0.2 and 0.4 s in critical-listening rooms.
- Real Decreto 1909/1981, por el que se aprueba la NBE-CA-81 sobre condiciones acústicas en los edificios (BOE); modificada como NBE-CA-82 por el Real Decreto 2115/1982
- ISO 11654:1997, Acoustics. Sound absorbers for use in buildings. Rating of sound absorption
This guide is for general information: it does not replace professional advice or compliance with the regulations that apply to your building. Product data is what manufacturers or listings publish on the date of consultation shown on each sheet, and it may change.