How to stop echo at home
Acústica en Casa · Updated on · 7 min read
A room’s echo is called reverberation, and it is fixed by absorbing sound, not by soundproofing. In this guide we look at how much echo is too much, why it appears, what you can do without building work, and how to choose and place acoustic panels using real data.
In this guide
Are there acronyms or technical terms you do not understand, such as NRC, RT60 or αw? We explain them step by step in our guide: Acoustics without jargon: what acronyms and numbers mean
What echo is and why it bothers you
When you speak in a room, the sound does not stop instantly: it bounces off the floor, walls and ceiling and reaches your ears again and again. That “tail” is called reverberation and it is measured with the RT60: the time it takes for sound to drop by 60 dB once the source stops.
Too much reverberation makes speech harder to understand: that is why the CTE limits reverberation time in classrooms and conference rooms and, in its Annex J, recommends placing absorbent material to improve it. In a home you notice it because voices are hard to follow, video calls sound hollow, and TV or music become tiring; it is typical of rooms with hard floors, smooth walls, large windows and little furniture.
How much echo is too much
There is no single figure: it depends on the use. For listening rooms and studios, the EBU Tech 3276 recommendation asks for a nominal RT60 between 0.2 and 0.4 s and, as a guide, Tm = 0.25 · (V/100)^⅓ s (the same formula appears in ITU-R BS.1116-3). The Spanish CTE DB-HR requires at most 0.7 s in empty classrooms and conference rooms under 350 m³, and 0.9 s in empty restaurants and dining rooms.
There is no published standard for living rooms and bedrooms. In our calculator we use, as our own guideline only, 0.4 to 0.6 s for a living room and 0.3 to 0.5 s for a bedroom.
Warning
These figures are for an empty room or one with its usual furniture. To know your room’s exact value it has to be measured; with our calculator you get an estimate.
Why it appears: the Sabine formula
RT60 depends on two things: the room’s volume (V) and how much sound its surfaces absorb (A, in “sabin” m²). The Sabine formula sums it up, and the CTE uses it too: T = 0.16 · V ÷ A. More volume means more echo; more absorption means less echo.
The absorption of each surface is its area times its absorption coefficient α (from 0 to 1, the fraction of sound it absorbs). These are reference values from the absorption tables commonly used in acoustics (Everest, Egan), compiled by Sengpiel Audio and Engineering ToolBox; they vary with the mounting and the specific product:
- Paint on plaster or brick: α ≈ 0.02 (almost everything bounces back).
- Tile or ceramic: α ≈ 0.02.
- Parquet: α ≈ 0.07.
- Plasterboard: α ≈ 0.05.
- Thick carpet on a hard floor: α between 0.3 and 0.6.
- Heavy curtains: α between 0.5 and 0.75 at mid frequencies.
With those data, a 5 × 4 × 2.5 m living room with parquet, painted walls and ceiling and moderate furnishings adds up to only about 4.7 sabin m² and has an RT60 of around 1.7 s: a lot of echo for watching TV or talking comfortably.
Solutions without building work, from least to most
Before buying anything, add absorption with what you already have or what is cheap:
- Textiles and furniture: sofas, thick curtains, rugs and bookcases break up reflections and absorb sound. A thick rug covering a good part of the floor brings that area closer to carpet values (α between 0.3 and 0.6) compared with 0.07 for parquet.
- Cover empty surfaces: a large bare wall facing another is where the echo is most noticeable.
- Acoustic panels: if that is not enough, they are the specific solution. They come in PET felt, slatted wood, foam and diffusers, and they stick or hang up without building work.
Tip
An acoustic panel absorbs echo inside the room; it does not stop noise passing into the next one. For that, read our guide on soundproofing doors and windows.
How to choose an acoustic panel: NRC, thickness and data
The NRC is a single-number absorption rating: the average of the coefficient across four bands (250, 500, 1000 and 2000 Hz) rounded to 0.05, as defined by the ASTM C423 and C634 standards. In Spain and Europe manufacturers usually give the αw, the weighted coefficient of the UNE-EN ISO 11654 standard, which the CTE also accepts. ISO 11654 itself states that a single number suits routine uses (offices, corridors, classrooms, hospitals), not environments that need careful acoustic design, where data by frequency is required. It also does not describe bass: a thin panel will not fix a “boom”.
Some manufacturers publish an NRC above 1. A NASA study on acoustic foam notes that reverberation-room tests sometimes measure Sabine coefficients greater than 1, which is often attributed to the diffraction effect at the edges of the sample. In our calculations we use 1 as the maximum, which is the cautious approach.
Look at three things: who states the NRC (the manufacturer with a test, or just the listing), the thickness (more thickness, better response towards bass) and how many m² each pack covers, because the price per panel is misleading. In the sheets of our panel catalogue we mark where each figure comes from.
How many panels you need and where to put them
The amount depends on the volume, the room’s materials and the RT60 you are aiming for. Our calculation is: subtract the absorption the room already has from the absorption you need for your target, and divide by what each m² of panel gains (its NRC minus the absorption of the wall it covers). In the example above, to go from 1.9 s to 0.5 s with a panel of NRC 0.55 you would need about 22.3 m², close to a third of the walls and ceiling.
In its recommendations for classrooms of up to 350 m³, the CTE (Annex J) places absorbent material on the ceiling and the rear wall “to minimise late echoes”. For a home, our placement guideline is similar: spread the panels over more than one wall, start with the wall behind where you sit or speak and the side walls, at head height, and if two walls face each other, cover part of both.
Tip
If the coverage that comes out is very high, combine the panels with rugs, thick curtains or diffusers, or aim for a more relaxed echo target. In our calculator, covering more than 40% of walls and ceiling is considered impractical.
Common mistakes
These are the mistakes that most often come up when trying to remove echo:
- Mixing up absorbing (correcting echo inside the room) with soundproofing (stopping noise passing from one room to another).
- Covering just one small wall with thin panels and expecting a big change.
- Trusting an NRC with no source or above 1.
- Buying by price per panel without looking at the m² in the pack or the thickness.
- Trying to fix bass with thin foam: more thickness or bass traps would be needed.
Related products
A selection from our catalogue related to this guide.
As an Amazon Associate, I earn from qualifying purchases.
TONOR
TONOR decorative wooden panels, set of 4 of 120×60 cm, teak
No verified acoustic data
- Material
- Wood / MDF
- Size per unit
- 120×60 cm
- Pack contents
- 4 units
- Pack coverage
- 2.88 m²
Set of four slat panels of 120×60 cm (2.88 m²) made of high-density polyester fibre, MDF and solid wood veneer. They can be cut to size and fixed with adhesive or the screws included.
Fstop Labs
Fstop Labs 12 acoustic foam panels, 30×30×5 cm
No verified acoustic data
- Material
- Acoustic foam
- Size per unit
- 30×30 cm
- Pack contents
- 12 units
- Pack coverage
- 1.08 m²
Twelve polyurethane foam panels of 30×30×5 cm with a 3D relief, which arrive vacuum-compressed and expand when opened. They cover roughly 1.08 m² of wall.
Rovson
Rovson 48 acoustic foam panels, 30×30×3 cm
Stated by the seller, with no verifiable test
- Material
- Acoustic foam
- Size per unit
- 30×30 cm
- Pack contents
- 48 units
- Pack coverage
- 4.32 m²
Forty-eight acoustic foam panels of 30×30×3 cm, designed to cover large surfaces in studios and offices. About 4.3 m² per pack and 2.3 kg in total.
Frequently asked questions
Do acoustic panels soundproof against the neighbours’ noise?
No. They absorb echo inside the room, but noise passing through walls and doors is only reduced with mass and sealing. See our guide on soundproofing doors and windows.
How many panels do I need for my living room?
It depends on the measurements, the materials and the echo target. Enter your measurements in the calculator and we give you square metres and packs.
Do rugs and curtains help?
Yes, they help: a thick carpet has α between 0.3 and 0.6 against 0.02–0.07 for a hard floor, and heavy curtains between 0.5 and 0.75 at mid frequencies. Often they are not enough on their own. With the calculator you can see how much the echo in your room changes when you add a rug or panels.
What NRC should I look for?
The higher, the more it absorbs, but who states it matters more. In our catalogue, panels with an NRC published by the manufacturer range from 0.48 to 0.65. Without a verified NRC, treat it as an approximate figure. What NRC means is explained in Acoustics without jargon, and you can see each panel’s data in the panel comparison.
Sources and further reading
What we rely on. The links open in a new tab. Consulted on November 21, 2026.
- CTE DB-HR, Protection against noise (Spanish Ministry of Transport, Mobility and Urban Agenda) — Reverberation time limits (2.2), the formula T = 0.16 V/A (3.2.2), αw (3.2.1) and the recommendations of Annex J.
- EBU Tech 3276, Listening conditions for the assessment of sound programme material — Listening rooms: nominal RT60 between 0.2 and 0.4 s and Tm = 0.25 (V/100)^⅓ (section 2.3).
- ITU-R BS.1116-3, Methods for the subjective assessment of small impairments in audio systems — The same Tm formula for listening rooms (8.2.3.1).
- Sengpiel Audio, Absorption coefficients of building materials — Reference table (Everest, Egan) of coefficients by frequency band; secondary source.
- Engineering ToolBox, Room sound absorption coefficients — Coefficient ranges by material; secondary source.
- NASA Technical Reports Server, Examination of the Measurement of Absorption Using the Reverberant Room Method for Highly Absorptive Acoustic Foam — Sabine coefficients above 1 in a reverberation room and their attribution to the edge effect.
- ISO 11654:1997, Acoustics — Sound absorbers for use in buildings — Rating of sound absorption (public preview) — Single-number αw and its scope (clause 1); paid standard.
- ASTM C634, Standard Terminology Relating to Building and Environmental Acoustics — Reference standard that defines the NRC; paid, not reproduced here.
- Intertek, ASTM C423: sound absorption by the reverberation room method
This guide is for general information: it does not replace professional advice or compliance with the regulations that apply to your building. Product data is what manufacturers or listings publish on the date of consultation shown on each sheet, and it may change.