Acoustics without jargon: what acronyms and numbers mean

Acústica en Casa · Updated on · 15 min read

Acoustic spec sheets are full of acronyms: NRC, αw, RT60, dB, Rw, STC… This guide explains them in plain language, with examples and the official definitions from the Spanish building code (CTE) and the standards, so you know what each one measures and which number to look at for your problem. At the end there is a dictionary with a direct link to every term.

First, the big mix-up: absorbing is not soundproofing

When someone says “I want to improve the acoustics of my home”, they may be talking about two very different problems. The first happens inside the room: sound bounces off hard surfaces and builds up, which is why voices boom or a conversation is hard to follow. The second happens between spaces: noise from neighbours or from the street goes through walls, doors and windows.

Each problem has a different fix. Echo is corrected by absorbing sound inside the room, with panels, curtains or rugs. Noise that passes from one space to another is reduced by soundproofing, that is, with mass and sealing. The Spanish building code itself, CTE DB-HR, treats them separately: it regulates sound insulation and, on its own, reverberation time and absorption.

Almost every acronym you will see on a spec sheet belongs to one of those two groups:

  • Absorption acronyms, for the echo inside the room: α, NRC, SAA, αw and RT60.
  • Soundproofing acronyms, for noise passing from one space to another: R, Rw, DnT,A, L′nT,w and, on American products, STC.

Tip

Before looking at any number, ask yourself whether your problem is the echo in the room or the noise coming in. If it is the second, acoustic panels will not solve it: see our guides on noise between neighbours and on doors and windows.

Decibels and hertz: how loud and what pitch

The decibel (dB) measures how loud a sound is, but not on an ordinary scale: on a logarithmic one. The CTE defines sound pressure level as Lp = 10 · lg (p² ÷ p₀²). The practical consequence is surprising: every 10 dB more means ten times the sound energy, and every 3 dB more almost doubles it (10 · lg 2 ≈ 3). That is why two devices that each sound at 50 dB do not add up to 100 dB, but to about 53.

dBA are decibels with a correction that imitates how the human ear hears. The CTE explains that A-weighting compensates for the ear’s different sensitivity at different frequencies: in its table, 100 Hz counts 19 dB less, while 1000 Hz is not corrected at all.

The hertz (Hz) measures frequency, that is, pitch. According to the CTE, frequency is the number of pulses of an acoustic wave occurring in one second. Few hertz are low sounds, like the boom of a bass drum; many hertz are high sounds, like a whistle. The CTE assesses insulation in frequency bands from 100 Hz to 5 kHz (5000 Hz).

Tip

A difference of a few decibels sounds small, but on a logarithmic scale it is a lot of energy. That is why acoustic improvements are measured in decibels and not in percentages.

The absorption coefficient (α): the number all the others come from

The CTE defines the sound absorption coefficient as the ratio between the acoustic energy absorbed by a material and the energy falling on it. It is written with the Greek letter α, read “alpha”, and in theory it goes from 0 to 1: at 0, all the sound bounces back; at 1, the material absorbs everything that reaches it. An α of 0.30 means it absorbs 30 % of the energy reaching it and returns the other 70 %.

The coefficient depends on frequency: the same material absorbs low, mid and high sounds differently. That is why there is never one single “true” number, and why the summary numbers in the next section exist. To get an idea, these are reference values from tables commonly used in acoustics, which change with the mounting and with the specific product:

  • Paint on plaster or brick: α ≈ 0.02, so almost everything bounces back.
  • Parquet: α ≈ 0.07.
  • Thick carpet on a hard floor: α between 0.3 and 0.6.
  • Heavy curtains: α between 0.5 and 0.75 at mid frequencies.

How is it measured? In a laboratory, following the ISO 354 standard, inside a reverberation chamber: a very reflective room. First, the time the sound takes to die away is measured with the room empty, and then with the sample installed. The difference between the two measurements gives the sample’s absorption, which is divided by its surface area and expressed in one-third-octave bands, which are very narrow groups of frequencies.

Multiplying α by the surface area gives the sound absorption (A) in m², called “sabins”. It is the piece the Sabine formula uses to calculate the echo of a room, as we explain in our guide to stop echo at home.

Warning

A laboratory α is only valid for the mounting it was measured with, for example the panel glued to the wall or spaced away from it. If the mounting is different, the result in your home will be different too.

NRC, αw and SAA: one number to summarise absorption

Since the coefficient α changes with frequency, there are several figures that summarise it in a single number. These are the three you will see on spec sheets and ads, each with its definition:

  • NRC (Noise Reduction Coefficient): the average of the coefficient α in the 250, 500, 1000 and 2000 Hz bands, rounded to the nearest multiple of 0.05. It is the usual one on products of US origin.
  • SAA (Sound Absorption Average): the average of the coefficient α in the 12 one-third-octave bands from 200 to 2500 Hz, rounded to 0.01. It belongs to the same ASTM C423 standard as the NRC.
  • The αw (“alpha w”, weighted sound absorption coefficient) is the figure of the ISO 11654 standard, the usual one in Europe. It is obtained by comparing the measured curve with a reference curve, and it is the value of that curve at 500 Hz. It is sometimes followed by the letters L, M or H, which warn that the product absorbs much more than the number suggests at low (250 Hz), mid (500 and 1000 Hz) or high (2000 and 4000 Hz) frequencies.

They are different scales, calculated with different bands and methods, and they are not interchangeable: an NRC of 0.7 and an αw of 0.7 do not necessarily describe the same thing. To compare two products, always use the same indicator for both.

ISO 11654 itself limits its scope: the single number is valid for routine uses, such as offices, corridors, classrooms or hospitals, but not for environments that call for careful acoustic design, where the complete data by frequency are needed. It is also not suitable below 250 Hz, so it does not describe the bass.

One last caution: some manufacturers publish an NRC above 1. A NASA study on acoustic foam indicates that coefficients greater than 1 are sometimes measured in the reverberation chamber and that this is usually attributed to the effect of the sample’s edges, so it should be taken with caution. You can see how we use these figures when choosing a panel.

Tip

A high NRC does not guarantee that a panel fixes the bass or the “boominess”: if your problem is low frequencies, always ask for the complete curve by frequency.

Reverberation and RT60: how long the echo lasts

Reverberation is the “trail” a sound leaves as it bounces around the room. The reverberation time, or RT60, is the time needed for the sound pressure level to drop by 60 dB after the source stops, according to the CTE definition. The CTE takes limit values to be the average of the values at 500, 1000 and 2000 Hz.

The bigger the room, the longer the sound takes to die away, and the more absorption there is, the shorter. This is summed up by the Sabine formula, the same one the CTE uses: T = 0.16 · V ÷ A, where V is the volume in m³ and A is the total absorption in m². That is why a living room with hard floors, bare walls and few furnishings booms more than a bedroom with curtains and carpet.

For reference, the recommendation of the European Broadcasting Union (EBU) for professional listening rooms points to an RT60 between 0.2 and 0.4 seconds. At home you do not aim for that much, but the principle is the same: less reverberation, clearer voices. You can calculate the RT60 of your room with our calculator.

Tip

If you want to reduce the echo in your living room, start by finding out how much you have: measure the room and use the calculator before buying anything.

The soundproofing acronyms: R, Rw, DnT,A, L′nT,w and STC

Soundproofing means making sure noise does not pass from one side to the other. The CTE distinguishes two types of noise crossing a wall or a floor: airborne noise (voices, television or music, which travel through the air) and impact noise (knocks and footsteps on the floor). The main acronyms, from the simplest to the most specific, are these:

  • R and Rw: the sound reduction index of an element (a wall, a door, a window) measured in the laboratory, in dB. Rw is the single number, calculated according to the ISO 717-1 standard. The higher, the better it insulates.
  • R′ (“R prime”): the same, but measured in the building, including indirect transmissions of sound. That is why it can differ from the laboratory figure.
  • DnT,A: the difference in dBA between the noise in one room and the next, corrected for reverberation time. It is the figure the CTE uses to measure airborne sound insulation between interior rooms. The higher, the better.
  • L′nT,w: the impact noise level reaching the room below. Here it is the other way round: the lower, the better, because it is a noise level and the CTE sets values that must not be exceeded.
  • STC (Sound Transmission Class): the American single number for airborne sound insulation, calculated with the ASTM E413 standard from laboratory tests under ASTM E90. It is similar to Rw, but it is calculated with a different standard and is not interchangeable.

One idea explains why an expensive door does not always fix the problem: the CTE calls a flanking element the adjacent element through which indirect sound transmission takes place. Noise also gets through gaps, joints and side walls, so the laboratory figure of a door or a window is only reached if it is well installed and well sealed. We cover it in our guides on doors and windows and on vibration from appliances.

Warning

A laboratory insulation figure describes the element perfectly installed. In your home, the result depends on the joints, the gaps and the walls around it.

How to read a product spec sheet without being misled

With the above you can now review any spec sheet with good judgement. These steps will help you tell a useful figure from a sales claim:

  1. Decide whether your problem is one of absorption (echo) or soundproofing (noise getting through) and look for the matching group of acronyms.
  2. Check which indicator the product gives (NRC, SAA, αw, Rw, STC…) and which standard it was measured with. If it cites no standard, you cannot compare its figure with another’s.
  3. Check who declares the figure: a laboratory test or just the seller’s ad.
  4. Look at the thickness and the square metres each pack covers, because the price per piece is misleading.
  5. Be wary of phrases like “reduces noise by 90 %”: it is not a defined acoustic quantity and it is worth asking what it refers to.
  6. Treat an NRC above 1 with caution and, if your problem is the bass, ask for the curve by frequency.

In the sheets of our catalogue we mark where each figure comes from and we do not show prices. You can see them in the sections for acoustic panels, doors and windows and vibration isolation, or compare products with measurable criteria in our comparisons.

Dictionary of acoustic terms

Here is the short meaning of each term, in alphabetical order. Each one has its own link, so the other guides on this site take you straight to its definition.

Airborne sound insulation
Protection against noise that travels through the air, such as voices or music. In the CTE it is measured between interior rooms with the DnT,A index, in dBA.
Decibel (dB)
The logarithmic unit used to measure the level of a sound. Every 10 dB more means ten times the energy; every 3 dB, almost double.
Decibel A-weighted (dBA)
Decibels corrected with the A-weighting, which compensates for the ear’s different sensitivity at different frequencies (CTE DB-HR, Annex A).
DnT,A
A-weighted standardised level difference between two interior rooms: airborne sound insulation measured in the building, in dBA. The higher, the better insulated.
Elastic strip
A strip of elastic material, at least 10 mm thick, placed between a wall and the floor, ceiling or other elements to interrupt the transmission of vibrations (CTE DB-HR, Annex A).
Flanking element
A building element adjacent to another through which sound passes indirectly. It is the reason a good door is not enough if the rest is not sealed.
Frequency and hertz (Hz)
The number of pulses of an acoustic wave per second. Few hertz are low sounds; many, high sounds.
Impact sound insulation
Protection against the noise of knocks and footsteps on a floor. The CTE measures it with the impact sound pressure level L′nT,w: the lower, the better.
L′nT,w
Standardised weighted impact sound pressure level, in dB. The lower, the better insulated against knocks and footsteps.
NRC (Noise Reduction Coefficient)
The average of the absorption coefficient in the 250, 500, 1000 and 2000 Hz bands, rounded to the nearest multiple of 0.05 (ASTM C423).
Octave band and one-third-octave band
Frequency intervals in which sound is measured. An octave band goes from one frequency to another that is double; the one-third-octave band is narrower (CTE DB-HR, Annex A).
Pink noise
Test noise whose spectrum, in one-third-octave bands, is a straight line with a slope of 0 dB per octave. It is used for standardised measurements (CTE DB-HR, Annex A).
Porous material
An absorbent material with a cellular, granular or fibrous structure that turns the energy of sound into heat through friction of the air with its surfaces (CTE DB-HR, Annex A).
R and Rw (sound reduction index)
Insulation, in dB, of a building element (wall, door, window) measured in the laboratory. Rw is the single number calculated according to the ISO 717-1 standard.
Reverberation and RT60
Reverberation is the trail a sound leaves in a room. RT60 is the time the sound level takes to drop by 60 dB when the source is cut off (CTE DB-HR).
SAA (Sound Absorption Average)
The average of the absorption coefficient in the 12 one-third-octave bands from 200 to 2500 Hz, rounded to 0.01 (ASTM C423).
Sabine and sabin
The Sabine formula, T = 0.16 · V ÷ A, relates reverberation time to the volume of the room and its total absorption, which is measured in m² or “sabins”.
Shape indicators L, M and H
Letters that may accompany the αw under ISO 11654 when the material absorbs much more than the single number indicates at low (L), mid (M) or high (H) frequencies.
Sound absorption (A)
The amount of acoustic energy, in m², that an object absorbs. It is calculated by multiplying the absorption coefficient α by the surface area of the material (CTE DB-HR, Annex A).
Sound absorption coefficient (α)
The ratio between the energy absorbed by a material and the energy falling on it. In theory it goes from 0 (everything bounces back) to 1 (everything is absorbed) and it depends on frequency.
STC (Sound Transmission Class)
The American single number for the airborne sound insulation of an element, calculated with the ASTM E413 standard from tests under ASTM E90. It is not interchangeable with Rw.
Weighted sound absorption coefficient (αw)
Weighted absorption coefficient according to the ISO 11654 standard. It is a single number, usual in Europe, that summarises the absorption of a material.

Related products

A selection from our catalogue related to this guide.

As an Amazon Associate, I earn from qualifying purchases.

Best value for money

TONOR

TONOR decorative wooden panels, set of 4 of 120×60 cm, teak

No verified acoustic data

Material
Wood / MDF
Size per unit
120×60 cm
Pack contents
4 units
Pack coverage
2.88 m²

Set of four slat panels of 120×60 cm (2.88 m²) made of high-density polyester fibre, MDF and solid wood veneer. They can be cut to size and fixed with adhesive or the screws included.

Best value for money

Fstop Labs

Fstop Labs 12 acoustic foam panels, 30×30×5 cm

No verified acoustic data

Material
Acoustic foam
Size per unit
30×30 cm
Pack contents
12 units
Pack coverage
1.08 m²

Twelve polyurethane foam panels of 30×30×5 cm with a 3D relief, which arrive vacuum-compressed and expand when opened. They cover roughly 1.08 m² of wall.

See all: Acoustic panels

Frequently asked questions

What does NRC mean on an acoustic panel?

It is the “noise reduction coefficient”: the average of how much the material absorbs in four frequency bands, rounded to 0.05. An NRC of 0.80 does not mean it removes 80 % of the noise in the room, but that, on average, the material itself absorbs 80 % of the energy reaching it. More detail in NRC, αw and SAA.

Is a high NRC or a high αw better?

They are different scales and cannot be compared with each other. Within each one, the higher, the more the material absorbs. Always compare products using the same indicator and the same standard. In the panel comparison we show which indicator each one publishes and who declares it.

What is the difference between absorbing and soundproofing?

Absorbing reduces the echo inside a room, and is measured with α, NRC, αw or RT60. Soundproofing stops noise from passing from one space to another, and is measured with Rw, DnT,A or STC. An acoustic panel absorbs, but does not insulate you from your neighbours. We cover this in the guide on noise between neighbours.

Can I trust a spec sheet that does not say which standard it was measured with?

Not for comparing. A figure with no standard, no indicator and no information about who declares it does not let you know what it measures or whether it is comparable with another product’s.

Is STC the same as Rw?

They are similar, because both summarise airborne sound insulation in a single number, but they are calculated with different standards (ASTM E413 and ISO 717-1) and are not interchangeable. More in the soundproofing acronyms.

Sources and further reading

What we rely on. The links open in a new tab. Consulted on November 23, 2026.

This guide is for general information: it does not replace professional advice or compliance with the regulations that apply to your building. Product data is what manufacturers or listings publish on the date of consultation shown on each sheet, and it may change.

More guides

Cookie settings

Choose which cookies you allow. You can change your choice at any time from “Cookie settings” in the footer. More information in the cookie policy.

Necessary

Always active

They store your choice about cookies. They are essential and cannot be switched off.

Form security (Google reCAPTCHA v3)

Protects the contact form against spam and automated submissions. It is loaded only on the contact page and only if you allow it. Google acts as our data processor and may process technical data (such as your IP address) outside the European Union. If you do not allow it, you can write to us by email.

Statistics (Google Analytics)

It helps us see which pages are visited and how people reach them, so we can improve the site. It is loaded through Google Tag Manager only if you allow it and sets the _ga and _ga_<container> cookies, which last up to 2 years. Google acts as our data processor and may process technical data (such as the IP address) outside the European Union. You can withdraw it whenever you like and we delete those cookies.